WHY MONITOR?
- Support during the construction and site phase by comparing design predictions with actual structural response.
- Instrumentation for static and dynamic testing (load testing) of the structure.
- Continuous monitoring for preventive and predictive maintenance of new structures.



DIAGNOSTIC SERVICES
- Supply and installation assistance.
- Support during the static testing phase of the structure.
- MODEL-DRIVEN service
- Non-linear FEM modeling of the structure and model updating following load tests.
- Identification of damage scenarios to define thresholds of increasing severity in relation to the ultimate safety of the structure.
- Continuous data processing via algorithms and activation of a 24/7 alerting service.
MONITORING SYSTEM
MEMS Inclinometers: 485
MEMS Accelerometers: 485
Displacement Transducers: 23
MEMS Accelerometers: 485
Displacement Transducers: 23